Basic Info
  • Model NO.: F360 Series
  • Operation: Electric Type
  • Arc-extinguishing Medium: RCCB
  • Structure: ELCB
  • Function: Circuit-Breaker Failure Protection, Overcurrent Protection, RCCB
  • Model: F360
  • Warranty Time: 2 Years
  • Delivery Time: 2 Weeks
  • Trademark: BSD
  • Origin: China
  • Breaking Capacity: Low Voltage Circuit Breakers
  • Speed: Normal Type Circuit Breaker
  • Installation: Insert
  • Poles Number: 4
  • Certification: VDE, ISO9001-2000, CE, UL, CCC
  • Specification: 16-63A ,10mA,30mA,100mA,300mA, 2P, 4P
  • Service: OEM ,ODM
  • Certificate: Ce ,ISO9001-2008
  • Transport Package: Standard Export Packing
  • HS Code: 8536200000
Product Description
Rccb F362 F364 model 2 pole 4 pole F360 earth leakage circuit breaker
 
 Application & Features

Elegant appearance, cover and handle in arc shape make comfortable operation.
Contact position indicating window.
In case of overload to protected circuit,RCCB handle trips and stays at central position, which enables a
 quick solution to the faulty line.The handle cannot stay in such position when operated manually.
Provides protection against earth fault/leakage current and function of isolation.
High short-circuit current withstand capacity
Applicable to terminal and pin/fork type busbar connection 
Equipped with finger protected connection terminals
Fire resistant plastic parts endures abnormal heating and strong impact
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated
 sensitivity.
Independent of power supply and line voltage, and free from external interference, voltage fluctuation.
 
 
Technical Data
Model: Electro-magnetic type
Residual Current Characteristics: A, AC
Pole No.: 2, 4
Rated Making and Breaking Capacity: 630A
Rated Current (A): 16, 25, 32, 40, 50, 63A
Rated Voltage: 240/415V AC
Rated Frequency: 50/60 Hz
Rated Residual Operating Current IΔn (A): 0.01, 0.03, 0.1, 0.3, 0.5 
Rated Residual Non-operating Current I Δno: 0.5I Δn
Rated Conditional Short-circuit Current Inc: 10kA
Rated Conditional Residual Short-circuit Current I Δc: 10kA
Tripping Duration: Instantaneous tripping ≤ 0.1s
Residual Tripping Current Range: 0.5 IΔn~10.5 IΔn
Terminal Connection Height: 19mm
Electro-mechanical Endurance: 4000 cycles
Connection Capacity: Rigid conductor 25mm²
Connection Terminal: 
Screw terminal
Pillar terminal with clamp
Fastening Torque: 2.0Nm
Installation: 
On symmetrical Din Rail 35mm
Panel mounting
 Specification:
Type Rated Current(A) LeakAge Acting Current Range of Break-off Rated Voltage
 SF362    16A,25A,32A,40A,63A    10mA,30mA,100mA,300mA    0.5~1.0  230V(220V)  
 SF364    25A,32A,40A,63A    30mA,100mA,300mA    0.5~1.0  230V/415V (220V/380V)